Technical specification
Super Ventilation 70S
(Pictures are for reference only)
NO.1 An overview
T17G is the most common and large trailer type smoke exhaust equipment in the industry. With its diversified configuration, the trailer type smoke exhaust machine is very suitable for ventilation and smoke exhaust in large warehouses, commercial buildings, high-rise buildings, subways, tunnels, underground parking lots, airports, public rehabilitation areas and other large places. Equipped with water mist generator, can spray water mist, quickly reduce the temperature of the fire site, and can suppress the strong, high temperature, toxic, flammable and other gases.
NO.2 Main performance parameters
Full load mass (kg): ≤3500
External dimension (mm): ≤4000*2000*2800
Maximum smoke extraction capacity (m³/h): ≥ 15,000-200,000 cubic meters/hour
Smoke discharge from the air outlet (m³/h): 150,000-200,000 cubic meters/hour
Endurance (hours): 4
Engine Power (kW): 108
NO.3 Main configuration
1. Trailer chassis
The braking system |
Collision braking system |
Parking system |
Manual parking system |
Maximum traveling speed: km/h |
80 |
Size of the trailer: mm |
≤4000*2000 |
2. Powertrain
Type: |
4L, DOHC, TCI, Timing silent chain, DVVT |
Number of engine cylinders: |
4cylinder |
Rated power: KW @r/min |
108/5500 |
Maximum torque: N. m @r/min |
205/4000 |
Endurance: h |
4h |
3. smoke extraction system
smoke exhaust rate: m³/h |
150000-200000 |
|
propeller |
Diameter: mm |
1300 |
Material |
CFRP |
|
Pitch motion |
Angle |
-10~20 |
control |
Electric control |
|
Water mist system |
Traffic: L/S |
5(According to the demand) |
4. electric control system
Power control system |
Wire controlled remote control:3m |
control the content |
Engine start and stop, oil volume display, fan pitch, emergency stop, lighting display, etc. |
5. Additional configuration
Air duct |
Positive pressure air duct |
1 root, 20 meters in length, foldable |
Negative pressure air duct |
2 root, 20 meters in length, foldable |
6. Water spray power: there are interfaces for external water supply.